Product Features
- Quickly removes rust and scale, saving time and reducing the risk of ignition.
- Effectively removes thick layers of rust.
- Dissolves rust and scale by breaking them down into a solution with water.
- Contains inhibitors to prevent corrosion, protecting metals such as iron, brass, bronze, rubber seals, and plastics.
- Can be diluted with water up to 4 times depending on the thickness of the rust and scale.
- Application methods include immersion or using a rotating pump.
Used with the following machinery
instruction
Rotating pump
- Mixing the Solution: Prepare the CHEMTEK SC-86 solution by mixing it with water in a ratio of 1:4. This means for every part of CHEMTEK SC-86, use 4 parts of water.
- Connecting to the Rotating Pump: Connect the rotating pump to the machinery or equipment that needs cleaning.
- Circulating the Solution: Start the rotating pump to circulate the CHEMTEK SC-86 solution throughout the equipment. Let it circulate for 2-3 hours to allow the solution to effectively dissolve rust and scale. If the solution loses effectiveness during this time, consider replenishing it with fresh solution.
- Rinsing with Clean Water: After the circulation period, rinse the equipment thoroughly with clean water until all residues of the cleaning solution are removed.
spray cleaning- Mixing the Solution: Prepare the CHEMTEK SC-86 solution by mixing it with water in a ratio of 1:5. This means for every part of CHEMTEK SC-86, use 5 parts of water.
- Spraying: Use a spray tank to apply the diluted CHEMTEK SC-86 solution evenly over the entire surface area that needs cleaning.
- Foaming and Dissolving: As you spray, you may notice foaming occurring as the CHEMTEK SC-86 interacts with rust. Allow the solution to dissolve the rust completely.
- Rinsing: After the rust has dissolved and the cleaning action is complete, rinse the surface thoroughly with clean water to remove any remaining residue.High-Pressure
- Washing: For more stubborn residues or thorough cleaning, you can use a high-pressure washer to rinse off the CHEMTEK SC-86 solution effectively.
Cleaning the rotating parts in a cooling tower and evaporative condenser involves several
- To reduce the water level in the tray of the Cooling Tower and Evaporative Condenser by approximately 20%Add CHEMTEK SC-86 solution to the tray in a ratio of 1 part CHEMTEK SC-86 to 4 parts water in the system.
- Turn off the fan of the machine and turn on the water pump. Allow the system to circulate for 1-2 hours. If the solution loses effectiveness, add more.
- Drain the water from the system.
- Refill the system with fresh water and circulate for 10-15 minutes, approximately 2 rounds.Refill the system with fresh water and operate the machine normally.
Video demonstrating the effectiveness of CHEMTEK SC-86